Method for Calculating the Potential Distribution of Nonlinear Ion Mirror and Modeling a Dust-Impact Mass Spectrometer

Piyakov, I., Rodin, D., Rodina, M.

Abstract. Dust-impact mass spectrometers are used to analyze the chemical composition of micrometeoroids and space debris particles. The focusing of charged particles packets produced by high-speed interaction is complicated because of their high energy spread. The focusing can be achieved by using high voltages, or using electrical fields with special distributions. The method of analytical calculation of such nonlinear distribution is given in this paper. The nonlinear electrostatic ion mirror with a given distribution of potential provides the temporal focusing of ions with an energy spread of up to 25 % of the accelerating voltage. To verify the focusing ability of the resulting potential distribution the trajec-tories of ions with different coordinates of origin and different initial energy spread were calculated. The mass resolution is calculated on the basis of ions trajectories and times of flight. The results of trajectories simulation allow us to conclude that nonlinear ion mirror provides sufficient level of temporal focusing to resolve simple substances such as aluminium, ferrum, lithium and other metals that can be detected in the chemical composition of micrometeoroids and space debris particles.

Keywords: dust-impact mass spectrometer, time of flight mass spectrometer, mass analyzer, nonlinear ion mirror, reflectron

GOST 7.1-2003 citation for works in English:Цитирование по ГОСТ 7.1-2003 для работ на английском языке:
Piyakov, I., Rodin, D., Rodina, M. Method for calculating the potential distribution of nonlinear ion mirror and modeling a dust-impact mass spectrometer // Instrumentation Engineering, Electronics and Telecommunications – 2016 : Proceedings of the II International Forum (Izhevsk, Russia, November 23–25, 2016). – Izhevsk : Publishing House of Kalashnikov ISTU, 2017. – Pp. 74–80.

GOST 7.1-2003 citation for works in Russian:Цитирование по ГОСТ 7.1-2003 для работ на русском языке:
Piyakov, I., Rodin, D., Rodina, M. Method for calculating the potential distribution of nonlinear ion mirror and modeling a dust-impact mass spectrometer // Приборостроение, электроника и телекоммуникации – 2016 : Сб. ст. II Междунар. форума (г. Ижевск, 23–25 ноября 2016 г.). – Ижевск : Изд-во ИжГТУ имени М. Т. Калашникова, 2017. – С. 74–80.

APA v6 сitation:Цитирование в формате APA v6:
Piyakov, I., Rodin, D., & Rodina, M. (2017). Method for calculating the potential distribution of nonlinear ion mirror and modeling a dust-impact mass spectrometer. In Instrumentation Engineering, Electronics and Telecommunications – 2016. Proceedings of the II International Forum (pp. 74–80). Izhevsk, Russia : Publishing House of Kalashnikov ISTU.

Scientific conferences Kalashnikov Izhevsk State Technical University
 
 

© Kalashnikov Izhevsk State Technical University, 2024

All rights reserved